Re: [ISTA] EFI / logger errrata
EFIlive is a Win 9x data display program written by Paul Blackmore; can
graph up to 12 parameters at a time. Available from:
http://www.starrperformance.com.au
Logger (L.EXE) is a DOS based ALDL data viewer & logger, written by me.
Uses serial port, therefore needs a special cable; Diacom cable will NOT
work. L.exe has *all* the ALDL data on the screen, not like Diacom w/ just
selections. Also records 0-60 times & max knock retard hit during a run.
Saves data in EFIlive format. At this point, EFI does not record SyTy
data, so that's why there's Logger. Some folks don't have Win capable
laptops in their trucks anyhow, so its a real basic prog.
Cable available as plans (free), parts kit (cheap) or all done (still
cheap) from:
http://www.mindspring.com/~amattei/akmelect.htm
That's about it.
Barry - Sy#26
At 04:53 PM 06/10/2000 -0400, the Sandman wrote:
>Hey Barry
>
>Could you please summarize this system in terms of capabilities, parts
>required, costs, sources, and comparison with Diacom?